YHAU-CW Double Effect Steam Fired Absorption Chiller
120-4,000 TR (422 TO 14,067 kW)
Enhanced efficiency and reliability for combined heat and power systems (CHP), commercial cooling and industrial process applications.
- Innovative, two-step evaporator and absorber with parallel flow cycle
- Flexible design and a wide operating envelope to handle lower steam pressures
- Variable-frequency drive (VFD) solution pump
Innovative Design for Superior Efficiency
YORK® YHAU-CW Double-effect, Steam-fired Absorption Chillers offer a broad range of capacities from 120 to 4,000 TR. This unit uses an innovative, two-step evaporator and absorber cycle along with a parallel flow cycle to improve efficiency and reduce the risk of corrosion. The double-effect design combined with a wide operating envelope allows it to handle a wide variety of steam pressures. And world-class engineering and service help to simplify chiller operation over the life of the system.
Benefits
OPTIMAL EFFICIENCY
The YHAU-CW Double-effect, Steam-fired Chiller uses an innovative, two-step evaporator and absorber design that enhances efficiency.
FLEXIBLE DESIGN
This unit is suited for a variety of steam pressures found in CHP systems, and commercial cooling and industrial process applications.
LOWER COST OF OWNERSHIP
World-class engineering and service teams reduce the cost of ownership by simplifying the operating cycle while providing added peace of mind.
Features
- Two-step evaporator and absorber design enhances absorption of the refrigerant into the concentrated solution, reducing overall pressure.
- Variable-frequency drive (VFD) solution pump provides superior part-load performance to reduce steam consumption versus constant-speed pumps.
- Control center with graphical, animated, LCD display offers past and present operational status, data recording and chiller safeties accessible at a touch.
- Parallel flow cycle enables lower lithium bromide solution concentrations, reducing crystallization risk and the potential for corrosion.
- High-temperature generator uses stainless steel tubes to maximize reliability by eliminating stress damage.
- Isolation valves on the suction and discharge of the solution and refrigerant pumps allow quick and easy servicing of pumps, which typically have a 60,000-hour life.
Two-step Evaporator and Absorber
YORK® YHAU-CW Double-effect, Steam-fired Chillers are uniquely designed with a two-step evaporator that has two pressure levels to divide the absorption process. The chilled water flows in tubes through the two evaporators while a concentrated lithium bromide solution is distilled in the absorber shell side in the opposite direction. This reduces the solution concentration and overall pressure, making the unit more efficient and reliable than conventional absorption chillers.
See How It Works
Parallel Flow Cycle
The parallel flow cycle divides the solution flow between the low- and high-temperature generators into two parallel, balanced paths. Combining our two-step and parallel flow design, the unit can achieve a safer and more efficient operation at a much lower pressure than conventional series-flow designs. Thanks to this innovative design, the LiBr concentration is lower. This results in a relatively low grade for the driving heat source, providing a high coefficient of performance (COP).
Learn More
Technical Resources
Document Name
Description
Language
Resource Type
Back
Next
Related Products
- Innovative YORK® two-step evaporator and absorber design enhances absorption of the refrigerant into the concentrated solution, reducing overall pressure and risks of crystallization.
- Lower pressure steam into the generator can be used to drive the absorption cycle for higher system efficiency.
- Solution plate heat exchanger optimizes efficiency by enabling effective heat transfer between the diluted and the concentrated lithium-bromide solutions.
- Innovative YORK® two-step evaporator and absorber design enhances absorption of the refrigerant into the concentrated solution, reducing overall pressure
- Lower temperature hot water source into the generator can be used to drive the absorption cycle for higher system efficiency
- Virtually eliminates crystallization risk and reduces the potential for corrosion
- Variable-speed driver delivers superior performance at both design and off-design conditions for higher efficiency
- Application flexibility of the chiller handles a wide range of leaving- and entering-chilled-water temperatures, fluid flows and steam conditions
- Modular configuration provides maximum flexibility, customization and compact footprint
- Two-step evaporator and absorber design enhances absorption of the refrigerant into the concentrated solution, reducing overall pressure
- Parallel flow cycle enables lower lithium bromide solution concentrations, reducing crystallization risk and the potential for corrosion
- Variable-frequency drive (VFD) solution pump provides superior part-load performance to reduce gas/oil consumption versus constant speed pumps