- YORK®
- Commercial Equipment
- Chilled Water Systems
- Absorption Chillers
- YHAU-CG/CA-CXR Double Effect Direct Fired Chiller/Heaters
YHAU-CG/CA-CXR Double Effect Direct Fired Chiller/Heaters
30-100 TR (105-352 kW)
The perfect combination of space-saving design and indoor/outdoor installation flexibility.
- A compact footprint for high-performance cooling and heating in tight spaces
- COP of 1.23 with a turndown ratio from 100% to 25% at different entering condenser water temperatures
- Simplified controls based on PLC and industry-standard MODBUS® connectivity for easy BMS integration
The Flexible Solution for Everyday Applications
YORK® YHAU-CG/CA-CXR Double-effect, Direct-fired Absorption Chillers/Heaters are driven by waste heat and low-cost heat to deliver highly efficient performance in a space-efficient design. The modular configuration allows multiple units to be arranged in a variety of footprints to fit different space requirements. And for easy building management system (BMS) integration, this unit comes with controls based on programmable logic controller (PLC) and industry-standard MODBUS® connectivity.
Benefits
FLEXIBLE DESIGN
Featuring a compact footprint and modular design, this unit is the perfect solution for high-performance cooling and heating in tight spaces.
OPTIMAL EFFICIENCY
This unit has a coefficient of performance of 1.23 with a turndown ratio from 100% to 25% at different entering condenser water temperatures.
TRUSTED RELIABILITY
World-class engineering and proven controls for easy BMS integration simplify operation and reduce unplanned maintenance downtime.
Features
- Coefficient of performance (COP) of 1.23 based on lower heating value (LHV) with a turndown ratio from 100% to 25%.
- The space-efficient design of the unit simplifies installation through forklift loading or via an emergency/service elevator.
- Low noise level of 80 dbA.
- Controls based on PLC and industry-standard MODBUS® connectivity for easy BMS integration.
- Ambient temperature range of 5°C/41°F to 40°C/104°F with 10-90% relative humidity.
- Modular configuration allows multiple units to be arranged in a variety of footprints to fit different space requirements.
- Completely packaged and insulated from the factory with an easy-access enclosure, making the unit suitable for outdoor installations.
Higher System Efficiency
If saving energy and reducing emissions are the goals of an organization, the YORK® YHAU-CG/CA-CXR is the perfect choice. This unit uses best-in-class burner combustion technology matched to a high-temperature generator furnace design that enhances system efficiency. It’s a perfect match for comfort cooling applications with low noise levels. The unit has a COP of 1.23 (LHV basis) with a turndown ratio from 100% to 25% at different entering condenser water temperatures.
Modular Configuration
The modular configuration of the YHAU-CG/CA-CXR allows multiple units to be arranged in a variety of footprints to fit different space requirements. This unique design feature also means it’s possible to incrementally increase capacity as buildings are constructed or spaces become occupied.
Technical Resources
Document Name
Description
Language
Resource Type
Back
Next
Related Products
- Innovative YORK® two-step evaporator and absorber design enhances absorption of the refrigerant into the concentrated solution, reducing overall pressure and risks of crystallization.
- Lower pressure steam into the generator can be used to drive the absorption cycle for higher system efficiency.
- Solution plate heat exchanger optimizes efficiency by enabling effective heat transfer between the diluted and the concentrated lithium-bromide solutions.
- Two-step evaporator and absorber design enhances absorption of the refrigerant into the concentrated solution, reducing overall pressure
- Parallel flow cycle enables lower lithium bromide solution concentrations, reducing crystallization risk and the potential for corrosion
- Variable-frequency drive (VFD) solution pump provides superior part-load performance to reduce gas/oil consumption versus constant speed pumps
- Innovative YORK® two-step evaporator and absorber design enhances absorption of the refrigerant into the concentrated solution, reducing overall pressure
- Lower temperature hot water source into the generator can be used to drive the absorption cycle for higher system efficiency
- Virtually eliminates crystallization risk and reduces the potential for corrosion
- Innovative YORK® two-step evaporator and absorber design enhances absorption of the refrigerant into the concentrated solution, reducing overall pressure
- Variable driving heat sources, such as jacket water from a gas engine, low- to high-pressure steam, direct-fired or exhaust gas
- Two types of YHAP-C absorption heat pumps are available: a heat amplifier (Type I) driven by high-temperature, and heat transformer (Type II) driven by medium-temperature