- YORK®
- Commercial Equipment
- Chilled Water Systems
- Air cooled Chillers
- YVFA Free Cooling Variable Speed Screw Chiller
YVFA Free Cooling Variable Speed Screw Chiller
150-500 TR (525-1,750 kW)
The YORK® YVFA is a free-cooling screw chiller that minimizes operating cost by combining superior engineering and technology with a packaged design that's simple to own and operate.
- YORK® variable-speed drive
- Air-to-liquid, free-cooling coils
- Intelligent controls optimize energy
Simple to Own and Operate
Advanced technologies, including a variable speed drive compressor, energy optimized hybrid cooling mode and air-to-liquid free cooling coils designed by our heat transfer experts, are intelligently controlled to maximize efficiency year-round.

Benefits

EFFICIENCY
Hybrid mode combines the best technologies to boost part-load efficiency.

SIMPLICITY
Packaged controls and single-point convenience simplify operation.

RELIABILITY
Get assured performance from the variable-speed leaders who have over three generations of expertise.

FAST PAYBACK
Payback possible in as little as two years – and we can prove it.
Features
- Packaged controls for single-point convenience to easily accommodate process or building changes
- Variable-frequency inverter technology enables a zero-inrush soft start and a high-displacement power factor across the entire operating range
- Performance is assured by AHRI certification, the first for an air-cooled screw chiller with free-cooling
- Open-loop and closed-loop design solutions for different building systems
- Intelligent controls also optimize the balance between using fans to move air over the free-cooling coils
- Quick Start option achieves full load after a power loss in four minutes or less
- Integrated air-to-liquid, free-cooling coils, designed by our heat transfer experts, reduce or eliminate the need for mechanical cooling when conditions allow
- 115-500 TR, 400-1750 kW
Quick Start
After power is interrupted, it can take a standard chiller up to 10 minutes to restart. But with the Quick Start feature, YVFA chillers can restart within seconds after power is restored. YVFA chillers feature an industry-leading compressor restart (upon power being restored) of 34 seconds.
Because YVFA chillers contain a variable-speed drive, there is no inrush of current. As a result, all compressors can be started together. This allows a faster ramp-up to full capacity than possible with a typical chiller.
Learn About Quick Start
Because YVFA chillers contain a variable-speed drive, there is no inrush of current. As a result, all compressors can be started together. This allows a faster ramp-up to full capacity than possible with a typical chiller.


Hybrid Mode Technology
Traditional free-cooling chillers use fixed-speed compressors that simply shut off when ambient temperatures are low enough. But this only saves energy when the compressors are completely shut off. Johnson Controls has pioneered a unique Hybrid Mode technology that optimizes energy use year-round. Using free-cooling coils to reduce the mechanical cooling load at a much higher temperature, the VSD compressors reduce speed and energy use more of the year for long-term performance and efficiency.
Free-cooling Technology
YVFA free-cooling, air-cooled chillers deliver the industry’s highest leaving water temperature to provide more tonnage in the same footprint as competing systems. And intelligently controlled free-cooling bypass valves reduce pump energy when free-cooling is not beneficial. These technologies enable the chiller to move from mechanical to hybrid to free-cooling modes automatically, further minimizing energy use.

Technical Resources
Document Name
Description
Language
Resource Type
Back
Next
Related Products
- Patented YORK® liquid-cooled, variable-speed drive technology
- Screw compressors designed and manufactured by Johnson Controls
- Patented, stepped VI (volume ratio) technology to match compressor operation to conditions
- Integrated compressor VSD standard with 50% fewer moving parts
- Excellent capacity control, high power factor and soft start
- Easy access to display and control features via control display access door
- Industry-leading IPLV with variable-speed drive fans
- Optimized compressor for better part-load efficiency
- Building automation system (BAS) communications
- Standard ambient range up to 125°F
- Optional hot-gas bypass
- Optional factory-mounted hydronic-pump kit