LONWorks® Adapter
CLW01
Integrate YORK® Variable Refrigerant Flow (VRF) remote control groups with LONWorks® building automation systems (BAS).
- Connect YORK® VRF systems to LONWorks® BAS networks for enhanced indoor equipment building management capabilities
- Connect up to 64 VRF remote control groups, or up to 160 indoor units with many network variables
Easy Integration With Your Existing Network
Enhance building performance and increase VRF system insights with the YORK® LONWorks® adapter. Connect up to 64 VRF remote control groups, or up to 160 indoor units with many network variables, to an existing LONWorks® BAS network. Enhanced BAS capabilities are integrated in all VRF indoor equipment to optimize control and performance. Control and monitoring points include: run/stop, operation mode, fan speed, temperature set point, prohibit zone controller functions, thermo status and alarm status.
Benefits
SIMPLE SYSTEM INTEGRATION
Easy setup connects YORK® VRF systems to existing LONWorks® BAS networks to streamline building management.
FLEXIBLE CONFIGURATION
Support up to 64 VRF remote control groups, or up to 160 indoor units with many network variables. Multiple adapters can be on the same H-LINK II segment.
ENHANCED CONTROL
LONWorks® network integration brings enhanced control and monitoring capabilities to indoor VRF equipment achieving increased performance and efficiency.
Features
- Easily integrates VRF system data into existing LONWorks® BAS network
- Connects up to 4 LONWorks® adapters simultaneously to the same H-LINK II segment
- Connects up to 64 VRF remote control groups, or up to 160 indoor units with a variety of network variables
- Connects up to 8 large and/or mini Central Controllers and/or LONWorks® adapters simultaneously to the same H-LINK II segment
Technical Resources
Document Name
Description
Language
Resource Type
Back
Next
Related Products
- Outstanding performance when outdoor ambient temperatures are as low as 14°F (-10°C) in cooling mode and as low as -13°F (-25°C) in heating mode
- Long refrigerant piping lengths – up to 1,640 feet total pipe run
- Advanced defrost cycle operation in heating mode
- Single-chassis units in 6, 8, 10, 12, 14 and 16 Tons enable system designs with fewer units and system sizes up to 36 Tons
- 54.3" height
- Optional wireless remote controller, wired zone controller, wired central controller or wired BMS adapter(s)
- Single-chassis units in 6, 8, 10, 12, 14 and 16 Tons enable system designs with fewer units and system sizes up to 36 tons
- Long refrigerant piping lengths provide design flexibility – up to 3,281 feet total pipe run and a vertical lift of 360 feet when the outdoor unit(s) is above the indoor unit(s)
- Dual-inverter compressors standard in 8, 10, 12, 14 and 16 Ton units for increased efficiency