- YORK®
- Commercial Equipment
- Ductless and VRF Systems
- Variable Refrigerant Flow Systems
- VRF Multi-Port Changeover Box (8 Ports)
VRF Multi-Port Changeover Box (8 Ports)
208/230V
The eight-port, variable, refrigerant-flow, change-over box accommodates future expansions and reduces potential material and labor costs.
- Continuous operation eliminates the risk of full system shutdown due to indoor unit malfunction
- Electronically controlled valves and fully insulated valve housing minimizes noise for quieter operation
- Eight-port system is ideal for medium-sized areas that require heating or cooling at various temperature settings
Greater Flexibility to Meet Design Needs
Easily accommodate future expansion with YORK® VRF Multi-port Changeover Box options. With multiple ports already in place, future mechanical and labor costs are reduced, offering effortless growth capabilities. The 8-port design is ideal for medium-sized areas that require various temperature settings. Continuous operation between heating and cooling efficiently recovers and transfers refrigerant vapor based on the demands of the area.

Benefits

SUPERIOR RELIABILITY
Continuous operation reduces risk of system shutdown even if one of the connected units malfunctions.

FUTURE-READY DESIGN
With multiple ports already in place, you can anticipate reduced labor and material costs as future expansion arises.

UNPARALLELED PERFORMANCE
Precise indoor comfort is delivered based on zone demands. Electronically controlled valves and a fully insulated housing reduce sound.
Features
- 8-port layout provides design flexibility and easily accommodates future expansion without added labor or material costs
- Fine mesh strainers protect valves and further increase reliability
- System operates using vapor instead of liquid, reducing number of valves required for increased simplicity
- Reliability optimized through continuous operation, so malfunction among connected units will not result in system shutdown
- Electronically controlled valves and fully insulated housing minimize noise and provide greater installation flexibility
- Simplified design provides easy service access to valves
Technical Resources
Document Name
Description
Language
Resource Type
Back
Next
Related Products
- Outstanding performance when outdoor ambient temperatures are as low as 14°F (-10°C) in cooling mode and as low as -13°F (-25°C) in heating mode
- Long refrigerant piping lengths – up to 1,640 feet total pipe run
- Advanced defrost cycle operation in heating mode
- Single-chassis units in 6, 8, 10, 12, 14 and 16 Tons enable system designs with fewer units and system sizes up to 36 Tons
- 54.3" height
- Optional wireless remote controller, wired zone controller, wired central controller or wired BMS adapter(s)
- Single-chassis units in 6, 8, 10, 12, 14 and 16 Tons enable system designs with fewer units and system sizes up to 36 tons
- Long refrigerant piping lengths provide design flexibility – up to 3,281 feet total pipe run and a vertical lift of 360 feet when the outdoor unit(s) is above the indoor unit(s)
- Dual-inverter compressors standard in 8, 10, 12, 14 and 16 Ton units for increased efficiency